BRIEF DESCRIPTION
PC12515 Abbott Belt Furnace, Work Area: 12"W x 4-3/4'H x 120" Heated, Model 2ZSCR-12-120HH2-2150, Electric, 480 Volt, 3 Phase, 102 KW, Max. Temp. 2150 deg.F., Allen Bradley SLC logic controller with "Panelview 900" operator interface flush mounted in the door of the enclosure. Two zones of control with a Honeywell UDC digital high limit control in each zone. Dissociated Ammonia mix and Dissociated Ammonia manifold are mounted on the side of the furnace. Variable speed wire mesh belt furnace. Entry has an atmosphere burn-off monitored by a Honeywell flame safety relay. Nitrogen atmosphere curtain box at the entry and an exhaust hood.
PC12513 Abbott Belt Oil Quench Furnace, Work Area: 6"W x 2"H x 60" heated, Electric, 480 Volt, 3 Phase, 78 KW, Max. Temp 1750 deg.F., Overall 5'W x 20'L x 84"H approx., . A Honeywell UMC 800 controller and operator interface, 3 Honeywell UDC 2000 high limit controllers, 3 SCR power controllers, An atmosphere panel is included with Nitrogen and Methanol flow meters. This furnace has a mesh belt with 1" high side flights that travels through an alloy muffle in the furnace.
PC12512 Can-Eng Atmosphere Belt Furnace, Work Area: 24"W x 8"H x 96"Heated, Electric, 575 Volt, 3 Phase, 288 KW, Overall 6'8"W x 8'10"H x 52'L, Max. Temp 2050 deg.F., Controls are mounted in a double door enclosure. There is an ABB "Commander 360" digital temperature controller for each of the 2 zones and a high limit controller for each zone. Amp meters are flush mounted in the door of the enclosure. Allen Bradley SLC 500 programmable logic controller controls all processes of the furnace. Two Halmar SCR power controllers.
PC12510 Can-Eng Belt Furnace, Work Area: 18"W x 12"H x 132" Heated, Model MBC 18111, Electric, 575 Volt, 3 Phase, 175 KW, Max. Temp 2050 deg.F., Overall 8'W x 7'H x 60'L approx., A double wide, 2 door panel contains the following pre-wired. 1 Barber Coleman digital controller for each of the two zones, 1 high limit controller, 1 chart recorder, Amp meters, belt speed controls, and power control for the tap transformers. Standard 2 zone mesh belt furnace with silicon carbide heating elements over and under the furnace belt.
PC12509 CI Hayes Belt-Atmosphere Furnace, Work Area: 14"W x 3"H x 90"Heated, Model BAC-03-14-90, Electric, 480 Volt, 3 Phase, 77 KW, 2100 deg.F. Max., Overall 4'8"W x 68"H x 32'8"L, There is a Honeywell UDC 3000 digital controller for each of the three zones and a one for the high limit. SCR power controllers for each zone regulates power to the elements. Allen Bradley SLC controls all functions of the furnace. The belt speed is controlled through a variable speed controller mounted in the enclosure. Waukee flow meters for Dissociated Ammonia and Nitrogen are located on the cooling chamber. Variable speed continuous belt furnace designed for use with Dissociated Ammonia and Nitrogen protective atmospheres.
PC12502 CI Hayes Continuous Belt Furnace, ID 12" X 8"H X 144"L, OVERALL 6'W X 6.5'H X 62.5'L, MAX. TEMP 2100 DEG.F., 575 VOLTS, 121 KW, 3 PHASE, ONTROLS: (3) BARBER COLMAN 560 DIGITAL TEMPERATURE CONTROLS, WATLOW OVERTEMPERATURE CONTROL AND BARBER COLMAN STRIP CHART RECORDER.
PC12468 Abbot Furn. Co. Sintering Belt Furnace, Model 5ZSCR-16-120PH2-168HH3-2400, Work Area: 16"W x 10'L Pre-Heat x 14'L High Heat x 18'L Cooling, Max. Temp, 2400°F, Electric, 480/3/60/260 KW, Controls: All mounted in free standing panel which includes the following: - Five (5) Honeywell UDC 2000 Digital High Limit Controllers - Five (5) Abbott "SCR" 3 Phase Power Controllers.
- Fifteen (15) Amp Meters with a range 0-75 Amps. (3 for each zone) - Panel has water cooled heat exchangers to keep controllers from over heating. - Honweywell Operator Interface Model: IWS-1603-HW - Honeywell PLC which controls temperature and process parameters ATMOSPHERE PANEL The following Waukee-Tronic Flow Meters are located on a separate panel attached to the cooling section. - 0 to 250 CFH Nitrogen Pre-Heat Injector - 0 to 250 CFH Hydrogen Mix Manifold Blend - 0 to 2000 CFH Hydrogen Manifold 100% - 0 to 2500 CFH Nitrogen Mix Manifold - 0 to 500 Nitrogen Curtain Box #1 & 2 Spray Box - Four (4) Dwyer Flowmeter for purge. Description: High temperature belt furnace with an alloy retort in the pre-heat section and a ceramic retort in the high heat section. There a total of five (5) zones with two (2) in the pre-heat and three (3) in the high heat. The high heat section is atmopsphere tight. This furnace is currently designed to be used with a ceramic belt which is not included with this furnace. Furnace can be modified to accept a wire mesh belt at an additional cost.
Condition: Very Good
PC12436

Sunbeam Belt Furnace,Work Area: 32"W x 18"H x 21'L Heated Length - 98"L load 1450 deg.F, 270 kW, Electric, Power Required: 480V/3 Phase/60 Cycles/270 KW, Overall Size: 72"W x 12'H x 47'L, table, 6'L cooling section with a water cooled heat exchanger. Zones: Four (4) w/a circulating fan in each zone.

PC11664 MRL Industries Belt Furnace, Model 14TF-186, Work Area: 14"W x 1-1/2"H x 186" Heated, Max. Temp. 1000 deg.C., Electric, 175 KW, 230 Volt, 3 Phase, Controls: MLS Microprocessor based control system. All set points, power levels, profiles and recipe selections are controlled through the system. (7) flow meters, air/nitrogen flow meters regulate flow to: Entry Curtain Top, Entry Curtain Bottom, Burn out zone 1, burn out zone 2, post firing, exit curtain top and exit curtain bottom, high limit protection provided by Anafaze Limit Controller. Standard continuous mesh belt conveyor with an Inconel 601 alloy muffle. Heated sections is divided into 11 zones of control. Load and Unload table 2' long each, Cooling section 8' long. Year of Manuf. 1995, Very Good Condition. Overall 51"W x 34'3"L x 53"H.
PC11764 Watkins-Johnson Belt Furnace, Work Area: 9"W x 2'H x 87" Heated, Electric, 600 deg.C., 480 Volt, 3 Phase, 32.4 KW, (6) Zones Controlled by Watkins Johnson WJ-988 multichannel microprocessor based temperature controllers and WJ-879 high limit control, belt speed control adjuster, (7) flow meters regulate flow of Nitrogen and Hydrogen, variable speed 1"-10" per minute, mesh belt, alloy mufle extends through hot zone, layout is 24" long load table, 87" long hot zone, 3" long precool, 36" water cooling, 24" atmosphere curtain box, 36" long unload table. Overall 40"W x 48"H x 20'3"L. Condition: Very Good.
PC11765 Watkins-Johnson Belt Furnace, Work Area: 24"W x 2"H x 25' Heated, Electric, 1100 deg.C., 208/230 Volt, 3 Phase, 100 KW, (8) Zones of control, Watlow model 988 digital temp. controller, Watlow "Anafaze" mutlizone high limit control, Leeds & Northrup multipoint strip chart recorder charts temp in each zone, belt speed control adjuster, (6) flowmeters regulate flow of Nitrogen and Hydrogen, variable speed mesh belt, alloy muffle extends through hot zone, layout is 84" long load table, 25' long hot zone, 12" long insulated pre-cool, 60" long water cooling, atmosphere curtain box and 84" long unload table. Condition: Very Good.
PC11945 Holcroft Belt Furnace, Work Area: 72" Wide x 9" high x 24' Long, Heated x 8' Long, H20 Cooling x 7' Long Blast Cool, Electrically Heated Atmosphere, 1650 deg.F., 460 Volt, 3 Phase, 900 AMPs, 717 KW, Conveyor Belt B-18-10-6-8 (314 S.S.) with 4"H side plates, balance weave wire mesh, Overall 9'W x 11'H x 56'L, Excellent Condition. Three zones of control with roof mounted fans in zone 1 & 2, furnace lining consists of 2000 deg.F. IFB and Kaowool, Zone 1 has 239 KW, zone 2 has 167 KW and zone 3 has 150 KW, Conveyor belt is supported by rollers on 16" centers and has belt speed of 5.92 feet to 35.5 feet per hour. Controls: All temp. controllers, SCR's power meters, etc.
BACK TO INVENTORY